Sign In | Join Free | My himfr.com
Home > Multi Parameter Patient Monitor >

ICU CCU Electric Multi Parameter Patient Monitor Class II GB/T18830-2009 Standard Blood Pressure Monitoring

Hunan Province Rainbow Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap ICU CCU Electric Multi Parameter Patient Monitor Class II GB/T18830-2009 Standard Blood Pressure Monitoring from wholesalers
     
    Buy cheap ICU CCU Electric Multi Parameter Patient Monitor Class II GB/T18830-2009 Standard Blood Pressure Monitoring from wholesalers
    • Buy cheap ICU CCU Electric Multi Parameter Patient Monitor Class II GB/T18830-2009 Standard Blood Pressure Monitoring from wholesalers
    • Buy cheap ICU CCU Electric Multi Parameter Patient Monitor Class II GB/T18830-2009 Standard Blood Pressure Monitoring from wholesalers
    • Buy cheap ICU CCU Electric Multi Parameter Patient Monitor Class II GB/T18830-2009 Standard Blood Pressure Monitoring from wholesalers
    • Buy cheap ICU CCU Electric Multi Parameter Patient Monitor Class II GB/T18830-2009 Standard Blood Pressure Monitoring from wholesalers
    • Buy cheap ICU CCU Electric Multi Parameter Patient Monitor Class II GB/T18830-2009 Standard Blood Pressure Monitoring from wholesalers

    ICU CCU Electric Multi Parameter Patient Monitor Class II GB/T18830-2009 Standard Blood Pressure Monitoring

    Ask Lasest Price
    Brand Name : RAINBOW
    Model Number : PM-9000GTA
    Certification : ISO13485, FSC
    Price : US $255-315/unit
    Payment Terms : L/C, T/T, Western Union, MoneyGram
    Supply Ability : 30000units/year
    Delivery Time : 5-8 days
    • Product Details
    • Company Profile

    ICU CCU Electric Multi Parameter Patient Monitor Class II GB/T18830-2009 Standard Blood Pressure Monitoring

    ICU CCU Electric Multi Parameter Patient Monitor Class II GB/T18830-2009 Standard Blood Pressure Monitoring

    Basic information:

    6 parametersECG,HR/PR,SPO2,NIBP,RESP, TEMP
    Size12.1 inch portable ICU monitor
    Gross Weight5kg(with lithium battery)
    Voltage220v
    Power40w
    Leads3-5 leads
    Suitable placesBedside care ward, ICU, CCU, operating theaters, emergency centers, family care and the like.
    Optional

    mobile stand/wall mount;Build-in thermal printer; lithium battery;ETCO2 module

    SFDA classificationClass II
    Working systemContinuous running equipment

    Features:

    1. 12" color TFT display, up to 12 waveforms

    2. Arrhythmia analysis, ST calculation, Pace analysis
    3. Various interfaces: A single guide, standard, large font, all leads

    4. Large volume of tabular and graphic trends information storage and easy to recall
    5. Anti-ESU, anti- defibrillator

    6. Patient info input management function

    7. Multi-lead ECG waveforms display in phase

    8. 1-7 level audio/visual alarming

    9. Built-in recorder and battery

    10. Suitable for adult, pediatric and neonatal patient
    11. New high-precision modules, new digital oxygen technology

    ICU CCU Electric Multi Parameter Patient Monitor Class II GB/T18830-2009 Standard Blood Pressure Monitoring

    Standard configuration:

    PM-9000GTA patient multi parameter monitor×1 set,

    Rechargeable lithium battery×1 pcs,

    standard 5-leads ECG conductance joint connecting cables×1 set,

    standard adult blood pressure cuffs×1 set,

    adult SPO2 probe×1 set,

    TEMP probe×1 set,

    power plug line×1 set,

    grounding wire×1 set,

    English operation manual×1 set.

    Three certificates×1 set.

    Technical parameters

    ECG

    lead mode;I,II,III,AVR,AVL,AVF,V1-6

    Gain: ×0.25, × 0. 5, and × 1, × 2

    Frequency: 0.5 Hz - 100 Hz

    Common-mode signal inhibition: More than 70 dB

    Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.

    HR: ± 5 BPM

    Precision calibration signal: 1mv(peak, ± 3% accuracy)

    ST Detection: measurement range (-2.0mV----+2.0mV)

    Using Standard: meet the ANSI / AMI EC13 -2002 standard

    Response time: 1s

    Alarm: Sound and Light

    Preset heart rate range: (Alarm over preset numerical)

    Ceiling: 1-255 bpm adjustable

    Threshold: 0-254 bpm adjustable

    NIBP

    Technology: Oscillography

    Mode: manual / automatic

    Measurement units: mmHg / kPa

    Scope: Pressure Cuffs 0-250 mmHg

    Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for newborn)

    Inflatable cuffs follow: original SBP: + 30 mmHg

    Measuring range: SYS: 60-250 mmHg

    DIA: 40-220 mmHg

    MEAN: 45-235 mmHg

    Response time: 1s

    Alarm: Sound and Light

    Preset range: report (Numerical exceed preset alarm)

    SYS: maximum: 1-255 mmHg adjustable

    Threshold: 0-254 mmHg adjustable

    DIA: ceiling: 1 -255 mmHg adjustable

    Minimum standards: 0-254mmHg adjustable

    SPO2

    Range: 0-100%

    Accuracy: 1%

    Resolution: 1%

    Pulse frequency: 20-250 times / min

    Response time: 1s

    Alarm: Sound and Light

    Preset range: (report Alarm over preset numerical)

    Ceiling: 1% - 100% adjustable

    Threshold: 0% - 99% adjustable

    TEMP

    Technology: thermostat temperature probe

    Measuring range: 20 ° C-45 ° C

    Temperature resolution: 0.1%

    Accuracy: ± 0.1 ° C

    Response Time: 1s

    Alarm: Sound and Light

    Preset range: report (numerical preset alarm over)

    Maximum: 20.1 ° C-45.5 ° C adjustable

    Threshold: 20 ° C-45.4 ° C Adjustable

    RESP

    Breathing frequency range: 0-60 bum

    Accuracy: ± 1rpm

    Response time: 1s

    Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches

    Alarm: Sound and Light

    Alarm range: (numerical preset alarm over)

    Ceiling: 10-100 bpm adjustable

    Threshold: 0 -99 bpm adjustable

    Printer(Optional)


    Specification: Dual channel thermal array data recorder

    Print mode: Real time or event triggered record waveform and text

    Accuracy: horizontal: 4oodpi vertical: 800dpi

    Annotation: Date/ time(24 hours)

    Optional wall bracket, mobile stand, visits backpack.

    System

    Screen:12.1 inches TFT screen of LCD

    Battery: sealed maintenance-free lithium battery

    Safety standard: lec601-1(GB9706.1)


    FAQ
    1. who are we?
    We are based in Hunan, China, start from 1997,sell to Domestic Market(50.00%),Southeast Asia(15.00%),Africa(10.00%),Central America(10.00%),Mid East(8.00%),South Asia(7.00%). There are total about 11-50 people in our office.

    2. how can we guarantee quality?
    Always a pre-production sample before mass production;
    Always final Inspection before shipment;

    3.what can you buy from us?
    Multi parameter Patient Monitor,ECG Machine,Infusion Pump,Syringe Pump,Nutritional Pump

    4. why should you buy from us not from other suppliers?
    Hunan Rainbow Technology Co,Ltd is a professional manufacturer and wholesaler in monitor with 19-year experience. In order to meets the marketing demand, our company cooperate with the America RMS Company to release a serials of PM-9000 parameters monitor.

    5. what services can we provide?
    Accepted Delivery Terms: FOB,EXW,Express Delivery;
    Accepted Payment Currency:USD,CNY;
    Accepted Payment Type: T/T;
    Language Spoken:English,Chinese

    Quality ICU CCU Electric Multi Parameter Patient Monitor Class II GB/T18830-2009 Standard Blood Pressure Monitoring for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hunan Province Rainbow Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)